Loading facility information
Loading facility information
Source: CMS · Released July 15, 2026
Every treatment needs a way into the bloodstream. A fistula is a connection made surgically in the arm. A catheter is a tube placed in a large vein. Fistulas last longer and get infected less, so they are generally preferred where a patient's veins allow one.
| Distance | Clinic | Also offers |
|---|---|---|
| 2.2 mi | DaVita Huber Heights Dialysis7769 Old Country Court, Huber Heights, OH 45424 | Home Hemodialysis · Peritoneal (PD) |
| 5.5 mi | DaVita Midwest Fairborn Dialysis1266 North Broad St., Fairborn, OH 45324 | Home Hemodialysis · Peritoneal (PD) |
| 7.2 mi | DaVita Fairborn Dialysis3070 Presidential Drive, Suite a, Beavercreek, OH 45324 | — |
| 8.0 mi | DaVita Five Rivers Dialysis4750 N Main Street, Dayton, OH 45405 | — |
Yes. This clinic trains patients for home hemodialysis and peritoneal dialysis. Training is a series of visits rather than a permanent move, and your nephrologist has to agree it suits you.
Yes — Medicare records chairs available after 5pm. Which specific times are free changes constantly and is published nowhere, so call to ask.
28 stations, meaning up to 28 people can be treated at once. A larger unit usually means more shift options. It says nothing about the quality of care.
Yes. Medicare places this clinic in the bottom 34% of US clinics. That is a position in a national distribution, not a score it passed or failed — most clinics sit in the middle band by design.
It is a for-profit facility operated by Fresenius Medical Care, Medicare-certified since 1990.
By calling. Chair availability, insurance acceptance and wait times are not published by Medicare, or by anyone else, for any clinic in the country. That is why the phone number is at the top of this page.
Every measure Medicare publishes about a dialysis facility, grouped in Medicare's nine categories and numbered for citation. Nothing here is selected. Where this clinic has no figure, the cell carries a dash and Medicare's code, and the codes are explained below the table.
| № | Measure | Patients | Clinic | US | OH | Reading |
|---|---|---|---|---|---|---|
| Anemia management | ||||||
| 01 | Medicare patients with hemoglobin < 10 g/dL | 46 | 33% | 21% | 25% | |
| 02 | Medicare patients with hemoglobin > 12 g/dL | |||||
This facility is one of 272 Ohio clinics rated as expected. The state has 288. Based on 197 patients.
Based on 197 patients.
These two do not add up to 100%. Some patients use a graft or another form of access. Access type depends on a patient's own veins, whether earlier attempts held, how soon surgery was available, and what the patient chose.
This facility is one of 97 Ohio clinics rated better than expected. The state has 270.
A ratio below 1 means fewer infections than Medicare expected for this clinic's patients. The published range is wide enough here to include the national expectation, which is why Medicare rates it as expected.
This facility is one of 118 Ohio clinics rated as expected. The state has 132. Based on 105 patients.
This facility is one of 285 Ohio clinics rated as expected. The state has 301. Based on 180 patients.
Listing depends on a patient's own health, what the regional transplant centre requires, and the patient's own choice — not on the clinic alone.
This facility is one of 287 Ohio clinics rated as expected. The state has 299. Based on 260 discharges.
This facility is one of 259 Ohio clinics rated as expected. The state has 264. Based on 186 discharges.
This facility is one of 289 Ohio clinics rated as expected. The state has 303. Based on 752 patients.
This facility is one of 20 Ohio clinics rated worse than expected. The state has 301. Based on 203 patients.
This facility is one of 251 Ohio clinics rated as expected. The state has 259. Based on 89 patients.
These are adjusted for how sick a clinic's patients are. For a clinic this size the published ranges are usually wide enough that the figure cannot be told apart from the national expectation.
This facility is one of 10 Ohio clinics rated worse than expected. The state has 81. Based on 70 patients.
Based on 46 patients.
| 8.3 mi |
| DaVita Dayton North Dialysis455 Turner Road, Dayton, OH 45415 |
|---|
| Evening Shifts |
| 46 |
| 0% |
| 1% |
| 1% |
| Dialysis adequacy | ||||||
|---|---|---|---|---|---|---|
| 03 | Adult hemodialysis patients with Kt/V ≥ 1.2 | 106 | 96% | 97% | 97% | |
| 04 | Adult peritoneal dialysis patients with Kt/V ≥ 1.7 | 61 | 96% | 92% | 93% | |
| 05 | Pediatric hemodialysis patients with Kt/V ≥ 1.2 | No figure published. Reason code 259. | 87% | 86% | ||
| 06 | Pediatric peritoneal dialysis patients with Kt/V ≥ 1.8 | No figure published. Reason code 259. | 78% | 77% | ||
| 07 | Pediatric hemodialysis patients with nPCR measured | No figure published. Reason code 259. | 91% | 92% | ||
| Infection | ||||||
|---|---|---|---|---|---|---|
| 08 | Standardized bloodstream infection ratio | 0.13 | Better than Expected | |||
| Mineral metabolism | ||||||
|---|---|---|---|---|---|---|
| 09 | Adult patients with hypercalcemia (calcium > 10.2 mg/dL) | 236 | 1% | 1% | 1% | |
| 10 | Adult serum phosphorus less than 3.5 mg/dL | 257 | 7% | 7% | 7% | |
| 11 | Adult serum phosphorus between 3.5-4.5 mg/dL | 257 | 21% | 22% | 21% | |
| 12 | Adult serum phosphorus between 4.6-5.5 mg/dL | 257 | 26% | 27% | 26% | |
| 13 | Adult serum phosphorus between 5.6-7.0 mg/dL | 257 | 30% | 26% | 27% | |
| 14 | Adult serum phosphorus greater than 7.0 mg/dL | 257 | 16% | 18% | 19% | |
| Patient experience | ||||||
|---|---|---|---|---|---|---|
| 15 | Nephrologists' communication and caring (stars, 1–5) | No figure published. Reason code 101. | ||||
| 16 | Quality of dialysis center care and operations (stars, 1–5) | No figure published. Reason code 101. | ||||
| 17 | Providing information to patients (stars, 1–5) | No figure published. Reason code 101. | ||||
| 18 | Patients' rating of the nephrologist (stars, 1–5) | No figure published. Reason code 101. | ||||
| 19 | Patients' rating of the dialysis center staff (stars, 1–5) | No figure published. Reason code 101. | ||||
| 20 | Patients' rating of the dialysis facility (stars, 1–5) | No figure published. Reason code 101. | ||||
| 21 | Survey response rate | No figure published. Reason code 101. | 24% | 23% | ||
| Staff vaccination | ||||||
|---|---|---|---|---|---|---|
| 22 | Healthcare personnel COVID-19 vaccination rate | No figure published. Reason code 201. | 4% | 2% | ||
| Survival & hospitalization | ||||||
|---|---|---|---|---|---|---|
| 23 | Mortality rate (per 100 patient-years) | 752 | 22 | 22.2 | As Expected | |
| 24 | Hospitalization rate (admissions) (per 100 patient-years) | 203 | 193.5 | 148 | Worse than Expected | |
| 25 | Readmission rate | 260 | 32.8% | 27.2% | As Expected | |
| 26 | Transfusion rate (per 100 patient-years) | 70 | 107.2 | 32.5 | Worse than Expected | |
| 27 | Standardized emergency department visit ratio | 89 | 1.05 | 0.99 | As Expected | |
| 28 | ED visits within 30 days of hospital discharge (ratio) | 186 | 1.01 | 1.04 | As Expected | |
| 29 | Standardized modality switch ratio | 61 | 2.48 | 1 | Better than Expected | |
| Transplant access | ||||||
|---|---|---|---|---|---|---|
| 30 | First-year kidney transplant waitlist ratio | 105 | 0.88 | 1 | As Expected | |
| 31 | Prevalent patients waitlisted for transplant | 180 | 16.5% | 16.5% | As Expected | |
| Vascular access | ||||||
|---|---|---|---|---|---|---|
| 32 | Adult patients with an arteriovenous fistula | 197 | 56.7% | 57.1% | As Expected | |
| 33 | Adult patients with a catheter in use 90+ days | 197 | 28% | 19% | 23% | |